Fire ratings, joist spans, slip testing, warranties and import logistics for hotel, rooftop and boardwalk projects.

This page is a working spec-and-sourcing reference for contractors, quantity surveyors, and procurement teams buying commercial composite decking for hotels, resorts, rooftop terraces, business districts, and boardwalks. It covers fire ratings, joist span tables, slip testing, warranty terms, and the import logistics checklist — everything a bid package needs, in checklist form.

What Is Commercial Composite Decking?

Commercial composite decking is decking manufactured from a wood-plastic composite core — recycled wood fiber bonded with polyethylene — engineered for public and high-traffic installations such as hotel terraces, rooftop bars, boardwalks, and restaurant decks, where load ratings, fire certification, slip resistance, and warranty terms are contract requirements rather than preferences.

Key Takeaways
  • Fire: EN 13501-1 Class Bfl-s1 or Cfl-s1, or ASTM E84 Class B, is the baseline you will see in typical tender documents; buildings over 18 m switch to non-combustible A2-s1, d0 systems.
  • Structure: commercial loading (200 psf / 9.6 kN/m²) tightens joist spacing from 16" OC to 12" OC on standard 1" composite deck boards.
  • Slip: specify a wet pendulum PTV of 36 or higher — grooved composite boards test around 45 PTV when saturated.
  • Warranty: commercial warranty terms on composite decking run 10 to 25 years; read the proration schedule and exclusions before you sign.

Residential deck boards and commercial boards look alike on a sample chip. The difference shows up in the paperwork: test reports, span tables, and warranty schedules written for public-traffic loading. If you are new to the product family, start with the board basics and terminology on our composite decking overview, then use this page to write the spec.

Fire Ratings for Commercial Decking: EN 13501 and ASTM E84

Fire classification is the first filter in commercial decking procurement because it is written into building control approvals, not negotiated at the site gate. Two systems dominate: the European EN 13501-1 reaction-to-fire classes (with the "fl" suffix for floorings) and the North American ASTM E84 flame spread classes.

EN 13501-1 flooring classes

Under EN 13501-1, floorings are tested with the radiant panel method (EN ISO 9239-1) plus the small-flame test (EN ISO 11925-2), and classified by critical heat flux:

ClassCritical heat fluxSmoke suffixWhere you will meet it
A1fl / A2flNon-combustible—Aluminium deck systems on high-rise terraces
Bfl≥ 8.0 kW/m²s1 / s2Bfl-capable polymer boards, e.g. Dura Deck Flip 150 marketed as Bfl-s1 within a Broof(t4) roof build-up
Cfl≥ 4.5 kW/m²s1 / s2The common commercial grade for wpc decking boards sold in Europe
Dfl≥ 3.0 kW/m²—Residential-only territory; reject for public decks
Efl / FflSmall-flame test only / fails—Not acceptable for commercial composite decking

Two points contractors get wrong:

  1. Bfl-s1 and Cfl-s1 are not the same board. Bfl requires roughly 80% more radiant heat to sustain flame spread (8.0 vs 4.5 kW/m²). The s1 suffix means very low smoke in the first minutes of fire exposure — the part of the test that matters for escape routes.
  2. System vs board ratings. Dura Deck Flip 150 is a good illustration: the board's standalone NBS Source data sheet lists reaction to fire as Cfl-s1 to BS EN 13501-1, while the manufacturer markets Class Bfl-s1 as part of a Broof(t4) roof assembly. When a tender says "Bfl-s1", ask whether it means the board alone or the installed system. The two answers are different products at different prices.

ASTM E84 flame spread classes

In the US market, spec sheets quote a Flame Spread Index from ASTM E84 (Steiner tunnel):

ClassFlame spread indexTypical product
Class A0–25Trex Refuge PVC decking (third-party tested to ASTM E84 Class A and ASTM E2768 ignition resistance, per Trex's launch documentation), aluminium deck boards
Class B26–75Trex Transcend, Trex Select, Trex Signature, Trex Enhance
Class C76–200Entry-grade composites; check before approving

Trex's QAI listing (B1109-1, current edition April 2025) covers its composite decking for both commercial and residential applications under ASTM E84-21 and CAN/ULC S102.2 — worth knowing because some US inspectors ask for exactly that listing reference in the submittal package.

The 18-metre rule (UK)

For buildings over 18 m, post-Grenfell guidance takes composite decking off the table: exterior balcony decking must be non-combustible, minimum A2-s1, d0. That means aluminium deck boards on pedestals or A2-class mineral boards. WPC decking boards, whatever their Bfl rating, stay on low- and mid-rise projects.

Bid spec checklist — fire:

  • [ ] Name the class: EN 13501-1 Bfl-s1 or Cfl-s1 (state board-only or system rating), or ASTM E84 Class A/B with the flame spread index.
  • [ ] Request the test report number, test house, and date — not just the certificate logo.
  • [ ] For buildings over 18 m: switch to A2-s1, d0 aluminium or mineral decking before the first design meeting.
  • [ ] Confirm the listing body (QAI, PFS-TECO, or equivalent) matches the local inspector's expectations.

Load Ratings and Joist Spacing for Commercial Composite Decking

Composite deck boards flex more than timber at the same thickness, and their stiffness drops as temperature rises — DuxxBak publishes a flexural modulus that falls from 620,000 psi at −20°F to 181,000 psi at 125°F, roughly a 70% loss across the range. Span tables therefore carry more weight in a commercial composite decking job than they do on a residential patio.

The two loading classes

  • 100 psf (≈ 4.8 kN/m²): residential decks, light-duty docks, playgrounds.
  • 200 psf (≈ 9.6 kN/m²): commercial decks, boardwalks, marinas, public walkways — the default for everything on this page.

Trex span table, verified against manufacturer data

Application (loading)1" and 0.875" boards2" × 6" boards
Residential, 100 psf16" OC24" OC
Commercial, 200 psf12" OC16" OC

Three follow-up rules from the same installation documentation:

  1. Diagonal layouts drop to 12" OC regardless of board thickness, because the effective span grows on the bias.
  2. Stairs are tighter than decks: Transcend 1"×6" treads 12" OC maximum; scalloped-bottom boards (Select, Enhance) 9" OC on stringers.
  3. Every board must bear on at least three joists. That rule kills 24" OC framing for standard boards on commercial loads by itself.

What this means on site

A hotel terrace spec that says "composite decking, 16" OC framing" is a residential spec with the wrong stamp. Write 12" OC for 1" boards at 200 psf, or 16" OC if you upgrade to 2"×6" profiles. Framing at 12" OC even where 16" would pass is common practice among installers in hot climates, because composite boards soften measurably in direct sun and the tighter grid keeps the surface flat under foot traffic.

Board-level strength numbers to quote in the spec: a solid 25 mm wpc decking board should land around 28–36 MPa flexural strength (Dura Deck Flip 150 publishes 35.1 MPa flexural strength and 2,894 MPa flexural stiffness to ASTM D7032-17). If the submittal you receive quotes no flexural values at all, treat it as a flag and ask for the test sheet.

Bid spec checklist — structure:

  • [ ] State the loading class (200 psf commercial) in words, not just "per manufacturer".
  • [ ] Fix joist spacing per the span table: 12" OC for 1" boards, 16" OC for 2"×6" at commercial loads.
  • [ ] Note diagonal areas and stairs separately; they require 12" and 9" OC respectively.
  • [ ] Require the board's flexural strength and stiffness test report in the submittal.
  • [ ] Write the thermal movement schedule into the spec: capped composite installation guides call for 4–6 mm end gaps, with longer runs taking wider allowances per the manufacturer's table.

Slip Ratings: Pendulum PTV, Ramp Classes, and Wet Balconies

Slip performance is a liability issue before it is a comfort issue. Two test methods appear in tenders, and they measure different things.

Pendulum test (PTV) — the wet-surface standard

The pendulum test (BS 7976, referenced in BS EN ISO 16165:2021) measures dynamic friction with a swinging slider that mimics a heel strike. The UK Slip Resistance Group classification:

Pendulum test value (PTV)Slip potential
0–24High
25–35Moderate
36+Low

The HSE position: outdoor areas exposed to weather — balconies, terraces, boardwalks — should hold a wet PTV of 36 or higher. For commercial projects, UK practice is to specify PTV ≥ 36 wet and dry, with the pendulum test accepted in UKSRG and HSE guidance as the standard measure when a slip claim reaches court.

Real test data published by UK decking specialists (Ultra Decking's flooded-surface stress tests): grooved composite decking holds about 45 PTV even saturated; premium wood-grain capped boards test at 36+ wet; classic wood-grain finishes can drop to 34 or lower when flooded. That 34 vs 36 gap is the difference between a passed tender and a failed one, so specify the surface, not just the product.

DIN 51130 ramp classes (R-values)

German R-ratings come from an oil-wetted walking ramp; the class is set by the angle where the test walker loses grip:

R-classRamp angleTypical specification
R96–10°Dry internal areas only
R1010–19°Areas kept mostly dry
R1119–27°Occasionally wet external areas
R1227–35°Wet commercial areas, pool surrounds, ramps
R13>35°Industrial wet areas

Two cautions. First, R-values are tested on an oiled ramp and do not transfer directly to rain-wet boardwalks — use PTV as the primary outdoor metric and treat the R-class as secondary. Second, some older UK briefs still quote a legacy "Quality Class C 28°" wording for decking — a term with no traceable standard behind it; treat it as obsolete and spec against the current UKSRG PTV bands instead. If a tender demands "28° ramp performance", that angle sits inside the R12 band (27–35°), so a board with an R12 ramp certificate plus wet PTV ≥ 36 covers the requirement in practice.

Bid spec checklist — slip:

  • [ ] Write "wet PTV ≥ 36 to BS 7976" with the slider type (Slider 96 for shoe traffic).
  • [ ] Choose the surface profile deliberately: grooved for wet boardwalks, wood-grain for sheltered terraces.
  • [ ] State groove orientation: boards run across the direction of travel for drainage.
  • [ ] Name the maintenance regime — leaves and algae film are the real slip hazard on any composite deck.

Board Specs That Matter in a Commercial Bid

A bid document only controls what it states. Here is the short list of physical properties worth writing down, with the numbers that separate commercial boards from residential stock.

Water absorption

Wood-plastic composite absorbs water at the cut ends and, in uncapped boards, across the surface. The standard check is a 24-hour immersion to ASTM D1037. Measured values for quality boards: 0.25% (Dura Deck Flip 150, 24 h), 0.33–0.41% (BamDeck test report), around 0.4% for commercial wpc decking samples. A spec of ≤ 0.5% (24 h, ASTM D1037) is realistic for capped boards. Note the honesty clause: the 24-hour figure measures near-surface uptake, not long-term saturation, and the same Flip 150 data sheet shows 1.48% at 28 days — which is why end caps and edge sealing belong in the installation spec. DuxxBak Commercial Dekk, an uncapped color-through board, publishes 1.0% (ASTM D1037) — still far below timber. Keep one method in the spec line: the cap-layer ASTM D570 figures in the table below and whole-board D1037 results are not interchangeable — quote D1037 for the board as shipped and request D570 as supporting cap data.

Capped vs uncapped

Co-extrusion changes the surface chemistry. Manufacturer-published comparison data (EcoTech, cross-checked against the independent test values above):

PropertyStandard wpc decking coreCapped co-extrudedTest method
Water absorption, 24 h2.0–6.0%≤ 0.3%ASTM D570
Surface hardnessShore D 55–65Shore D 72–80ASTM D2240
Color shift after 500 h QUVΔE 8–12ΔE ≤ 3ASTM G154
Flexural modulus2,500–3,800 MPa5,500–7,000 MPaASTM D6109

For hospitality work — sun decks, pool terraces, marina boardwalks — capped boards are the defensible default: the cap is where scratch, stain, and fade resistance live, and those are the three things a hotel facilities manager complains about first. Budget 15–30% extra over uncapped stock.

Commercial composite decking specification comparison — deck boards on a hotel terrace

Three commercial boards, side by side

SpecDura Deck Flip 150Trex Transcend (commercial)DuxxBak Commercial Dekk
Profile150 × 25 mm, 3,660 mm, hollow or solid1" × 5.5" (and 2×6 variants)Oversized commercial profile
Fire ratingBfl-s1 in Broof(t4) system; Cfl-s1 standalone (EN 13501-1)ASTM E84 Class BASTM E84 tested, PFS-TECO listed
Load designMax span 400 mm (manufacturer datasheet; loading class not published — confirm before framing)200 psf commercial tables100 psf deck, 750 psf stair treads
Water absorption0.25% (24 h), 1.48% (28 d)Capped shell1.0% (ASTM D1037)
Density1.25 g/cm³—1.2 g/cm³
Warranty15 years10 years commercial (25 yr on railing/cladding)Lifetime limited → 25-year prorated structure

If your project brief names one of these three products, that is your compliance target; if it names none, write the properties (fire class, span, PTV, water absorption) instead of the brand, and let the supplier match the numbers.

Commercial Warranty Terms: 10 to 25 Years, Read the Fine Print

Commercial warranty coverage on composite decking is shorter than the residential headline numbers — and that surprises first-time specifiers. The 50-year residential warranties evaporate on a hotel deck.

Supplier / lineCommercial termNotes
Trex decking (sold after 1 Jan 2023)10 yearsTrex Signature railing and Transcend cladding carry 25 years commercial; warranties transfer on property sale
Fiberon decking (commercial use)10 years performance + 10 years stain & fadeRailing drops to 5 years
DuxxBak Commercial DekkLifetime limited → 25 yearsYears 1–10 full product value, years 11–25 straight-line prorated, coverage continues at the year-25 rate afterwards
Dura Deck Flip 15015 years
Envision Distinction25 years commercialFull commercial warranty on a boardwalk-grade product

What the fine print takes back

Warranty documents are shorter on promises than marketing pages. Standard exclusions to plan around:

  • Labor is never covered. Replacement product only; removal, installation, and freight come out of your maintenance budget. A 10-year warranty with labor excluded is a materials warranty, not a cost warranty.
  • Proration reshapes the value. The DuxxBak structure is typical of the honest ones: full value for years 1–10, then a depreciating share to year 25. A defect claim in year 18 refunds a fraction of the board price.
  • Commercial use voids residential terms. Installing a residential-warrantied board on a restaurant terrace cancels the coverage you thought you bought. Check the "commercial application" definition — Trex defines it as any installation other than an individual residence.
  • Visible defects must be rejected pre-installation. Claims on boards installed with visible flaws are routinely declined; the site inspection before fixing is part of the warranty process.

Bid spec checklist — warranty:

  • [ ] Quote the commercial term (10/15/25 years), not the residential number.
  • [ ] Attach the full warranty document to the contract; the marketing summary is not the warranty.
  • [ ] Confirm transferability if the client may sell the building.
  • [ ] Budget maintenance on the assumption that labor and freight are never covered.

Composite Roof Decking and Balconies: Weight, Pedestals, and Structure

Rooftop terraces are where commercial composite decking earns its keep — and where the structural engineer gets the first and last word. The key figure for a roof is not strength but weight per square metre.

Weight per square metre, worked from board data

  • Hollow 150 × 25 mm board at 2.6 kg/m (typical supplier data) — Cladco's own 4 m hollow board weighs 11.2 kg, which is 2.8 kg/m: at 150 mm cover width, roughly 6.7 boards per m² → 17–19 kg/m² of deck area.
  • Solid 140 × 25 mm board, 4.4 kg/m: ≈ 7.1 boards per m² → around 30 kg/m².
  • Aluminium joists at 400 mm centres (≈ 0.39 kg/m): adds roughly 1 kg/m².
  • Pedestals at a 500 mm grid, 0.23–0.49 kg each: adds 1–2 kg/m².

A complete pedestal-mounted composite roof decking build-up therefore lands around 20 kg/m² with hollow boards and 32–33 kg/m² with solid boards — between a quarter and a sixth of a 50 mm concrete paver terrace (120–130 kg/m²). System ratings follow the same restraint: standard pedestal terrace systems are verified to > 4.0 kN/m² (about 85 psf) uniformly distributed load — adequate for terraces and light commercial use, but below the 200 psf (9.6 kN/m²) deck load class this page sets for public walkways, so the deck system rating and the structural design are two separate checks. That weight saving is the pitch to the structural engineer when an existing roof is being converted: a roof that cannot carry pavers can often carry composite decking on pedestals without reinforcement.

Composite roof decking on a pedestal-supported rooftop terrace

Pedestal system numbers to specify

  • Heavy-duty adjustable pedestals are rated to about 1,000 kg each, with wide bases (around 200 mm) to spread point loads onto the roof membrane.
  • System-level ratings: RYNO's terrace system quotes uniformly distributed load > 4.0 kN/m² standard (up to 7.5 kN/m²) and concentrated loads > 2.0 kN. Check the system certificate against your project's design load — the top of that range (7.5 kN/m²) sits below a 200 psf deck load (9.6 kN/m²), so do not assume headroom on the heaviest applications.
  • Height adjustment from ~10 mm up to 1,000 mm handles falls-to-drain and step changes around roof plant.
  • Self-levelling heads correct slopes up to 5%; rubber base mats (≈ 3 mm) protect the membrane; the deck stays demountable so the roof membrane can be inspected and repaired.

Balcony decking on existing structures

Balcony work is refurbishment-led: the structure already exists, so the question is whether it carries the new deck. The checklist form:

  • [ ] Get the existing slab's residual capacity confirmed — a balcony decking upgrade adds 20–33 kg/m² depending on board profile, plus live load.
  • [ ] Specify hidden-clip fastening: balconies are visible from below, and through-fixed boards routinely get rejected at design review.
  • [ ] For buildings over 18 m: composite balcony decking is out — A2-s1, d0 aluminium decking is the compliant route.
  • [ ] Keep balustrade fixings through the pedestal system or substructure, never through the waterproofing.
  • [ ] Write the slip spec (wet PTV ≥ 36) into the balcony package; exposed balconies are the exact case the HSE guidance names.

Hotels, Resorts, and Boardwalks: What Real Projects Specify

Published projects show which specs survive contact with a real site. Four examples, with the numbers:

Wild Dunes Resort, Isle of Palms, South Carolina. A 24,000 ft boardwalk system rebuilt with MoistureShield Vantage composite decking, grooved boards on hidden fasteners, six stair sets and one ADA-compliant ramp, completed in roughly five months. Chosen over timber for saltwater resistance and near-zero maintenance on a AAA Four Diamond property — evidence that the spec conversation in coastal hospitality is about maintenance hours, not board price.

Jumeirah Corniche, Dubai. Delivery logistics, not installation, defined this job: a five-metre-wide boardwalk running 14 km across six residential communities — at the time the longest in the Emirate — with Trex Transcend supplying the decked sections (27,000 m²) on a just-in-time schedule. The lesson for contractors: at this scale, the decking order is a delivery-schedule problem before it is an installation problem.

Malmaison Hotel, Brighton, UK. The requirement that drove this job was 25+ years of service in salt spray. The hotel replaced weathered hardwood with 450 m² of Hyperion Frontier composite decking across sea-front terraces and room balconies, installed in four weeks. Balcony decking packages like this one are the repeat-order backbone of the hospitality segment.

Balcony decking on a hotel balcony — commercial composite deck boards in coastal service

City Harbor, Guntersville, Alabama. An ipe supply failure, not a design preference, put composite on this project: the developer switched to Envision's Distinction collection for 50,000 sq ft of boardwalk plus 3,000 sq ft of event patios, secured with a full 25-year commercial warranty. When timber prices or availability spike, boards with 25-year commercial terms become the cost-competitive fallback.

Garden and grounds packages. The same procurement logic extends to hotel garden terraces, restaurant gardens, and villa developments: garden decking in capped boards with wood-grain or light-tone finishes carries restaurant traffic, irrigation overspray, and sun exposure without staining schedules. Where decks run alongside water features, pool surrounds, or fountains, see our pool deck specification notes — the slip and joist rules tighten again near the water line.

The Contractor's Procurement Checklist: Bid Spec to Delivery

Consolidating the page into one pass list, in order of execution:

  1. Write the spec by property, not by brand. Fire class (EN 13501 Bfl-s1/Cfl-s1 or ASTM E84 Class A/B), loading (200 psf), joist spacing (12" OC for 1" boards), wet PTV ≥ 36, water absorption ≤ 0.5% (24 h), warranty term (10–25 years commercial).
  2. Request test reports in the submittal. Fire classification report, slip test (BS 7976 pendulum), flexural strength/stiffness (ASTM D7032), water absorption (ASTM D1037). Certificates without report numbers get rejected.
  3. Run the sample approval loop. Order lab samples before the contract (A4 chips plus one full board section per color), check color under daylight, approve in writing, and keep the approved sample as the acceptance reference. Co-extruded boards arrive with batch shading — agree the tolerance in advance.
  4. Confirm factory credentials. ISO 9001/14001, CE marking, FSC chain-of-custody for recycled-content claims, and SGS/Intertek test history are standard asks of a wpc decking exporter.
  5. Fix MOQ and mix. Typical export MOQs run 200–500 m². Mixed colors and profiles usually ship in whole-pallet increments — round your take-off to pallet multiples before quoting. For budgeting, co-extruded commercial boards from Chinese factories list around $2.8–2.9 per linear metre for a 140 × 23 profile — roughly $20 per m² of deck area before freight; treat listing prices as the opening position for FOB negotiation.
  6. Lock the lead time. Published production times: about 15 days for a 20' container, 25 days for a 40' — plus inspection days. A June-opening hotel terrace ordered in May is already late.
  7. Agree payment terms in writing (next section — this is where most deals go wrong).
  8. Book third-party inspection. SGS, BV, or Intertek pre-shipment inspection on the first container, and on any repeat container if the board mix changes.
  9. Get the loading plan. Palletized, shrink-wrapped, board ends protected; a 40' high cube carries on the order of 2,700–3,300 boards of a 140 × 23 profile — roughly 850–1,100 m² depending on length. Confirm the per-container square metres with the factory and plan site offloading against that number.
  10. Order spare boards. Add 5–8% over the take-off for cuts, defects rejected on site, and future repairs — composite batches are never perfectly rematchable years later.
  11. Set delivery milestones tied to payment milestones, with the balance against documents (next section).
  12. File the warranty documents with the maintenance handover pack; the warranty clock starts at purchase, not installation.

For the supplier-facing half of this checklist — factory shortlists, audit visits, FOB terms, and how a sourcing order is structured — see our supplier and factory guide.

Payment Terms and Delivery Milestones for Bulk Orders

Import payment structures for commercial decking follow the standard China building-materials pattern. The default that reputable factories accept:

  • 30% T/T deposit against a proforma invoice to start production.
  • 70% balance before shipment, against a copy of the bill of lading plus the inspection certificate and packing list.
  • Orders over roughly $100k can move to sight L/C; small first orders under ~$20k may use Trade Assurance or escrow.

For multi-container programs, a three-milestone structure is commonly negotiable: 30% deposit / 30% after passed pre-shipment inspection / 40% balance against B/L copy. Get any variant confirmed on the proforma invoice, not in a chat message.

Milestone timeline (typical, 40' container)

MilestoneTimingTrigger documents
Contract + depositT+0PO, proforma invoice, 30% T/T
Sample approvalT+1–2 weeksApproved sample record, batch color sign-off
ProductionT+2–6 weeksFactory loading photos if requested
Pre-shipment inspectionT+5–7 weeksSGS/BV/Intertek report
Balance paymentBefore releaseB/L copy, inspection report, packing list
Shipment—Original B/L set or telex release
Sailing+20–40 daysVessel schedule, arrival notice
Site deliveryArrivalCustoms clearance, delivery to store

Payment safety rules (non-negotiable)

  • [ ] First order with a new factory: never more than 30% deposit, never 100% prepayment.
  • [ ] Pay only to the company account named on the business license; personal accounts are a refusal point.
  • [ ] Verify bank details by phone using an independently found number before wiring — invoice-fraud substitution is the most common loss on first orders.
  • [ ] Link every payment to a document (proforma, inspection report, B/L copy), never to a promise.
  • [ ] Split multi-container orders into per-container payments to cap exposure.

Frequently Asked Questions

Q: What fire rating does commercial composite decking need?

For low- and mid-rise commercial projects, specify EN 13501-1 Class Bfl-s1 or Cfl-s1 (or ASTM E84 Class B, flame spread 26–75) and request the test report with the submittal. Buildings over 18 m require non-combustible A2-s1, d0 decking such as aluminium, not composite boards.

Q: What joist spacing is required for commercial composite decking?

At commercial loading (200 psf), standard 1" composite deck boards require 12" on-center joists; 2"×6" boards may use 16" OC. Diagonal layouts require 12" OC, and stair treads are tighter again at 9–12" OC depending on the profile.

Q: How long is the warranty on commercial composite decking?

Commercial warranty terms run 10 to 25 years: Trex and Fiberon decking carry 10-year commercial warranties, Dura Deck Flip 150 carries 15 years, and Envision Distinction carries a full 25-year commercial term. Labor, removal, and freight are excluded, and prorated structures (such as DuxxBak's year-11–25 scale) reduce later claim values.

Q: How much does composite roof decking weigh, and is it suitable for existing roofs?

A pedestal-mounted composite roof decking build-up weighs roughly 20 kg/m² with hollow boards and 32–33 kg/m² with solid boards — between a quarter and a sixth of a 50 mm concrete paver terrace (120–130 kg/m²) — which often allows existing roofs to be converted without reinforcement. A structural engineer must still confirm residual capacity, and the deck should stay demountable for membrane access.

Request a Quote


About the Author — Wpc Decking Trade Technical Team

Camille Dubois — 12+ years in WPC composite decking production and export sourcing.

Sourcing WPC Decking?

Send your specification, quantity, destination and timeline. Fides routes the request to relevant WPC decking companies.